SERIES LPC 2090 - XXXX
|
|
|
|
Dash numbers are assigned according to customer inputs on details such as : enclosure type N12, N4, N4X; remote alarm relays; light, medium, heavy, and extra heavy duty; other requirements.
Customer inquiry is invited for advice and recommendations on the proper model choice for the application.
|
|
|
|
|
|
|
|
|
AC POWER LIGHTNING AND SURGE PROTECTIVE DEVICES (SPD)
FOR SINGLE & THREE PHASE, TO 1000 VRMS, 50/60 Hz SERVICE
- For use at : service entrance, transfer switch, distribution panels, and directly on the equipment itself requiring protection; at service entrance for line side or load side of the main disconnect means.
- Instantaneous and automatic in operation, no re-setting required. Conduction of overvoltage condition starts immediately and extinguishes the instant the transient passes. Response is less than one nanosecond. Protection provided in all applicable modes, L – L, L – N, L – G, N – G.
- Gapless – no spark gaps. High energy, multiple, solid state devices are used for dependable protection of sensitive equipment. There is no impulse breakdown voltage.
- KVA unlimited. The SPD is connected across the power lines on any KVA rated source or load. Series impedance (inductors, resistors, etc.) not used.
- No power follow current : The SPD conducts transients and stops conduction the instant the line voltage returns to normal.
- Bipolar operation. Clamping voltages are of same value in either polarity of the transient.
- The SPD provides protection against transients coming in on the power lines or generated from within the facility.
- Routine testing not required. Periodical maintenance not required. The SPD has no moving parts and draws no power current. The condition of the SPD is continuously self-monitoring with indicator lamps and optional remote alarm relays installed in each phase : These show whether or not the TVSS is operational.
- Life of the SPD generally exceeds the life of the equipment being protected.
- Surge Current (8/20 µs wave) ratings per mode to 240,000 amperes. Special designs for ultra critical applications are rated equivalent to 1,200,000 amperes per mode.
- Indicator lamps and remote alarm relays (provided with NO and NC contacts).
- Temperature range -55° to +170° F; altitude to 20,000 ft.
- SPD is completely enclosed in appropriate enclosure for any specified environment: outdoor, indoor, water hose down, corrosive atmosphere, explosive atmosphere.
- Detailed specifications are provided for each specific model.
- Lightning Protection Corporation designs and manufactures under strict quality control measures of ISO 9001-2000, registration certified by Underwriters Laboratories, File No. A5103.
|
|
|
|
|
|
 |
|
|
|
|
|